Possible solutions and hints
- Replace the motor on a trial basis.
- Check cable connections.
- Run in jog mode without load.
If these measures do not help, the fault is usually in the power stage of the drive module.
Further error messages can be found in the alarm list, which is available for download at the end of this page.
Possible solutions and hints
- Heat the device with an external source. If it then turns on, this indicates a weak power supply that needs to be repaired.
- Check fuses
- Check the voltage supply of 3 x 200 or 220 volts depending on the model.
Further error messages can be found in the alarm list, which is available for download at the end of this page.